Perancangan Struktur Kontrol Penggilingan Batubara pada Sistem Pembakaran Batubara

Stefanus Yudi Irwan, Awang Noor Indra Wardana, Ester Wijayanti

Abstract


The inability of the coal mill control structure to monitor and control pulverized coal flow causes operational and environmental problems. The research was done to design the new control structure for coal mill in coal firing system to achieve an improvement on control system performance compared to the existing control structure. Cascade control, blend station, and feedback control was used to control the flow of coal, the flow of primary air, and temperature of the pulverized coal. The result of the evaluation shows that the new control structure capable of fulfilling all the control objectives applied to it. Implementation of the new control structure capable to make the step response of the coal mill to have an average settling time at 161.75 seconds with 0% overshoot. The new control structure also capable to make the pulverized coal fineness at the range of 70% to 75% and moisture content at the range of 2.18% to 2.28%. The result of the evaluation makes the control performance of the new control structure is better than the previous coal mill control structure.


Keywords


pulverized coal; coal mill; control structure; control objective; control performance

Full Text:

PDF

References


V. Agrawal, B. K. Panigrahi, dan P. M. V. Subbarao, “Review of control and fault diagnosis methods applied to coal mills,” J. Process Control, vol. 32, hal. 138–153, 2015.

S. Y. Irwan dan A. N. I. Wardana, “Distributed Coal Mill Simulator based on IEC 61499,” di dalam The 5th UGM International Conference of Science and Technology, 2019.

N. Rees dan G. Fan, “Modelling and control of pulverised fuel coal mills,” Therm. Power Plant Simul. Control, hal. 63–100, 2011.

V. Agrawal, B. K. Panigrahi, dan P. M. V. Subbarao, “A unified thermo-mechanical model for coal mill operation,” Control Eng. Pract., vol. 44, hal. 157–171, 2015.

Zadiraka, “Pulverizer Control System,” 1985.

H. Tore, “The Blend station-a new ratio control structure,” Control Eng. Pract., vol. 9, hal. 1215–1220, 2001.

Y. Lee, S. Park, dan M. Lee, “PID controller tuning to obtain desired closed loop responses for cascade control systems,” Ind. Eng. Chem. Res., vol. 37, no. 5, hal. 1859–1865, 1998.

D. E. Seborg, T. F. Edgar, dan D. A. Mellichamp, Process Dinamics and Control, 4th ed. Wiley, 2017.




DOI: https://doi.org/10.17529/jre.v15i3.14605

Article Metrics

Abstract view : 53 times
PDF - 11 times

Refbacks

  • There are currently no refbacks.


View My Stats

 

Creative Commons License

Jurnal Rekayasa Elektrika (JRE) is published under license of Creative Commons Attribution-ShareAlike 4.0 International License.