Performa Konfigurasi Modul Surya Seri dan Seri Paralel pada Kondisi Mismatch Karakteristik Arus-Tegangan (I-V) terhadap Daya Output

Nurlaila Amna, Ira Devi Sara, Tarmizi Tarmizi

Abstract


The installation of a Solar Power System (PLTS) within the ideal conditions still uses the type of solar module with the same current and voltage characteristics. However, these ideal conditions can be different if the commonly used modules are no longer available on the market. Once there is damage or interference in the operating system, such as cracks in the module plate, it will take a significantly long time to replace. This particular condition can obstruct electrical power distribution to its intended loads in the other end. Therefore, creating a robust solar panel system that operates at its maximum capacity requires an alternative or approach to find such a similar module replacement. It is expected that the replacement module will have the I-V characteristics, which relatively resemble that of the earlier module and can help to maintain the energy availability of the solar panel system. This study aims to analyze which factors affect the characteristic irregularity of currents and voltages in a solar panel installation towards the output of a solar panel under certain conditions. The solar panel system is designed using 20 solar modules with each capacity is 250 WP power that is simulated with Simulink. The method creates the mismatch condition of the current and voltage on the solar module in a specific panel configuration. These mismatch conditions are created by combining solar modules with different currents and voltages in the Series (S) and Series-Parallel (SP) configurations. The simulation is carried out by replacing the main solar module with a 5% to 100% replacement solar module. The selection of the replacement module is based on Isc, which is close to the same because the current flowing in the series circuit is the same. The simulation results showed that the solar panel system still functioned properly and produced maximum power under mismatch conditions. Of all three configurations with mismatch conditions, it is found that the best performing configuration works with the Series-Parallel (SP) configuration of the STC conditions. The maximum power which can be sustained with Series-Parallel (SP) configuration reaches up to 40% of the original modules.


Keywords


mismatch of PV; irradiance; characteristic of PV

Full Text:

PDF

References


C. Herndon, Y. Erkaya, C. Xin, I. Flory, S. Dhali, and S. X. Marsillac, “Smart combiner for fixed commercial photovoltaic systems using power line communication,” in 2014 IEEE 40th Photovoltaic Specialist Conference, PVSC 2014, 2014.

P. Manganiello, M. Balato, and M. Vitelli, “A Survey on Mismatching and Aging of PV Modules: The Closed Loop,” IEEE Trans. Ind. Electron., 2015.

H. Ziar, S. Farhangi, and B. Asaei, “Modification to wiring and protection standards of photovoltaic systems,” IEEE J. Photovoltaics, 2014.

S. Filippo and J. S. Akilimali, “Are Manufacturing I–V Mismatch and Reverse Currents Key Factors in Large Photovoltaic Arrays,” vol. 56, no. 11, pp. 0278-0046, 2009.

B. Veerasamy, T. Takeshita, A. Jote, and T. Mekonnen, “Mismatch Loss Analysis of PV Array Configurations under Partial Shading Conditions,” 7th Int. IEEE Conf. Renew. Energy Res. Appl. ICRERA 2018, vol. 5, pp. 1162–1183, 2018.

Solmetric Corporation, “Guide To Interpreting I-V Curve Measurements of PV Arrays,” Appl. Note PVA-600-1, p. 23, 2011.

N. Yadav and D. K. Sambariya, “Mathematical Modelling and Simulation of Photovoltaic Module Using MATLAB/SIMULINK,” 2018 9th Int. Conf. Comput. Commun. Netw. Technol. ICCCNT 2018, pp. 1–6, 2018.

Teuku Murisal A, Ira Devi S and Suriadi, “Metode Maximum Power Point Tracking (MPPT) dan Boost Converter Memggunakan Fuzzy Logic Controller (FLC) pada Modul Surya,” Jurnal Rekayasa Elektrika (JRE), vol. 17, no. 1 Maret 2021, pp. 1–6, 2021.

A. N. Hamoodi and R. A. Mohammed, “Photovoltaic Modeling and Effecting of Temperature and Irradiation on I-V and P-V Characteristics,” vol. 13, no. 5, pp. 3123–3127, 2018.

M. A. bin H. M. Yakup and A. Q. Malik, “Optimum tilt angle and orientation for solar collector in Brunei Durassalam,” Renew. Energy, vol. 24, no. 2, pp. 223–234, 2001.

A. Tomar, S. Mishra, and C. N. Bhende, “Techno-economical analysis for PV based water pumping system under partial shading/mismatching phenomena,” 2016 IEEE 7th Power India Int. Conf. PIICON 2016, 2017.

M. Amin, J. Bailey, C. Tapia, and V. Thodimeladine, “Comparison of PV array configuration efficiency under partial shading condition,” 2017 IEEE 44th Photovolt. Spec. Conf. PVSC 2017, pp. 1–4, 2018.

D. Pera, J. A. Silva, S. Costa, and J. M. Serra, “Investigating the impact of solar cells partial shading on photovoltaic modules by thermography,” vol. 700, pp. 1979–1983, 2018.




DOI: https://doi.org/10.17529/jre.v17i4.22467

Article Metrics

Abstract view : 0 times
PDF - 0 times

Refbacks

  • There are currently no refbacks.


View My Stats

 

Creative Commons License

Jurnal Rekayasa Elektrika (JRE) is published under license of Creative Commons Attribution-ShareAlike 4.0 International License.