Measurement of Ankle Brachial Index with Oscillometric Method for Early Detection of Peripheral Artery Disease

Ervin Masita Dewi, Gema Ramadhan, Robinsar Parlindungan, Lenny Iryani, Trisno Yuwono

Abstract


Peripheral Arterial Disease (PAD) is a blood vessel disease caused by blockage or plaque accumulation around the artery walls. PAD is included in the category of diseases that are often diagnosed too late and affect more severe cases, such as the death of certain tissues or body parts. The Ankle Brachial Index (ABI) is an accurate non-invasive method for diagnosing PAD, in practice, ABI is usually performed in certain hospitals and is still difficult to find due to limited tools. Therefore, a tool is made that can detect the condition of a person's PAD based on the ABI value. The tool is made using two MPX5050GP sensors to detect oscillometric pulses, a DC pump and solenoid valve as an actuator to pump and deflate the cuff, ADS1115 as an external ADC to increase the accuracy of sensor readings, as well as an LCD and buzzer as tool indicators. The output is displayed in the form of a print out from a thermal printer, with an emergency stop that functions as a safety system to power off the supply when a failure occurs in the measurement process. Oscillometric method is used to detect systolic and diastolic pressure. The accuracy of the tool is 95.5%. This accuracy result is obtained by comparing the readings of systolic and diastolic values using a sphygmomanometer which is commonly used.


Keywords


Peripheral Arterial Disease; Ankle Brachial Index; Oscillometric

Full Text:

PDF

References


P. A. Griadhi, Sistem Kardiovaskuler, Denpasar: Fakultas Kedokteran Universitas Udayana , 2016.

Y. A. Habibie, “Peripheral Arterial Disease; What Should We Know?,” Nasional Symposium & Workshop “Aceh Surgery Update 2”, Banda Aceh, 2017.

E. Aryani dkk, "Hubungan Antara Dislipidemia Dengan Status Penyakit Arteri Perifer (Pap) Pada Pasien Diabetes Melitus Tipe 2 Terkontrol Sedang," Jurnal Diponegoro Vol.5 no.4 , Oktober 2016.

E. Decroli , "Iskemia Pada Jari Tangan Penderita Diabetes Melitus: Suatu Keadaan Peripheral Arterial Disease," Jurnal Kesehatan Andalas, Vol. 4, No. 2, Pp. 654-658, 2015.

Paul Muntner et al. “Measurement of Blood Pressure in Humans A Scientific Statement From the American Heart Association.” Hypertension. 2019;73:e35–e66. DOI: 10.1161/HYP.0000000000000087

Miname, M et al. “Different methods of calculating ankle-brachial index in mid-elderly men and women: the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).” Brazilian journal of medical and biological research vol. 49,12 (2016): e5734. doi:10.1590/1414-431X20165734

Kevin T. Nead et al. “Alternative Ankle-Brachial Index Method Identifies Additional At-Risk Individuals.” Journal of the American College of Cardiology Vol. 62, No. 6, 2013, http://dx.doi.org/10.1016/j.jacc.2013.04.061

Philip S. Lewis. “Oscillometric measurement of blood pressure: a simplified explanation. A technical note on behalf of the British and Irish Hypertension Society.” Journal of Human Hypertension (2019) 33:349–351, doi.org/10.1038/s41371-019-0196-9

Chandrasekhar, Anand et al. “Formulas to Explain Popular Oscillometric Blood Pressure Estimation Algorithms.” Frontiers in physiology vol. 10 1415. 21 Nov. 2019, doi:10.3389/fphys.2019.01415

D. I. Fauzi, "Rancang Bangun Portabel Tensimeter Dan Elektrokardiograf Berbasis Mikrokontroller Arduino," Tugas Akhir Fakultas Matematika Dan Ilmu Pengetahuan Alam Institut Teknologi Sepuluh Nopember Surabaya , Surabaya, 2017.

H. Y. Hendrayana, . M. A. Riyadi Dan Darjat, “Rancang Bangun Alat Pengukur Tekanan Darah Otomatis Menggunakan Metode Oscillometry Berbasis Raspberry Pi Model B+,” Transmisi, Vol. 18, No. 1, Pp. 38-42, 2016.

C. Chua And S. M. Hin, "Digital Blood Pressure Meter," Freescale Semiconductor, Singapore, 2005.

A.J. Puspitasari, "Rancang Bangun Blood Pressure Monitor Menggunakan Metode Osilometri Dengan Sensor Tekanan Mpx5050gp," Tugas Akhir Fakultas Matematika Dan Ilmu Pengetahuan Alam Institut Teknologi Sepuluh Nopember , Surabaya, 2015.

Assa'idah And Y. Adnan, "Investigasi Terhadap Kemampuan 2 Tipe Adc," Jurnal Penelitian Sains, Vol. 12, No. 2, Pp. 1-5, 2009.

D. Haryanto, "Analog To Digital Converter," In Teknik Antar Muka Adc, Pp. 1-8.




DOI: https://doi.org/10.17529/jre.v18i2.25758

Article Metrics

Abstract view : 0 times
PDF - 0 times

Refbacks

  • There are currently no refbacks.


View My Stats

 

Creative Commons License

Jurnal Rekayasa Elektrika (JRE) is published under license of Creative Commons Attribution-ShareAlike 4.0 International License.