KAJIAN RESPON JEMBATAN DI ACEH UTARA TERHADAP GEMPA BERDASARKAN DATA MIKROTREMOR

Zaki Mutaram, Umar Muksin, Yunita Idris

Abstract


The parameters of the bridge's resistance to dynamic loads, such as natural frequency and damping ratio, were determined by theoretical and experimental modal analysis. Microtremor measurements were performed on two types of bridges: steel truss bridges and reinforced concrete bridges. The goal is to establish the value of the bridge's dynamic characteristics as well as the bridge's feasibility based on SNI 2833-2008's natural vibration period limit. The natural frequency of the dynamic test is used to compare natural frequencies to theoretical frequencies to determine the condition of the integrity and level of stiffness of the structure or structural elements. The HVSR (Horizontal to Vertical Spectral Ratio) approach is used to analyze microtremor data on the ground, while FSR (Floor Spectral Ratio) and RDM (Random Decrement Method) analysis is used to analyze microtremor data on bridges. According to the findings of the first case study, the natural frequency of the soil is 1.25–1.35 Hz. The steel truss bridge's natural frequency value from the FSR is 0.81–3.29 Hz, while the RDM values are 1.12–3.46 Hz, indicating that the frequency produced is less stable on the NS component. The damping ratio is 2.02–4.97% in this case. The same analysis was carried out on a different type of bridge in the second case study, with a natural ground frequency of 1.11 - 1.47 Hz. The reinforced concrete bridge's natural frequency value from the FSR is 2.21 - 3.62 Hz, and the RDM results are 2.30 - 3.62 Hz. In each component, the frequency found tends to be stable. The damping ratio result is 2.05 - 4.81%. The period of the experimental results shows identical results to the period of the theoretical calculation results, with the average experimental result period being 7.24% greater than the period of the theoretical calculation results. According to the experimental data, the bridge damping ratio is around 3.16% . This result is in accordance with the literature, which is around 2-5%.

Keywords


Bridge; Microtremor; Natural Frequency; Resonance

Full Text:

PDF

References


Arintalofa, V., Yulianto, G. dan Harmoko, U. 2020. Analisa mikrotremor menggunakan metode HVSR untuk mengetahui karakteristik bawah permukaan manifestasi panas bumi Diwak dan derekan berdasarkan nilai Vp. Jurnal Energi Baru dan Terbarukan, 1(2), pp. 54-61.

Cantieni, R. 1983. Dynamic load tests on highway bridges in Switzerland. Rep, 211, Eidgenossische Material-prufungs-und Versuchsantalt (EMPA), Dubendorf, Switzerland.

Citak, S. O., Ohori, M., & Nakamura, T. 2012. Microtremor measurements and earthquake response analysis on Urado bridge, In The 15th World Conferences of Earthquake Engineering LISBOA, Kochi, Japan.

Gosar, A. 2007. Microtremor HVSR study for assessing site effects in the Bovec basin (NW Slovenia) related to 1998 Mw5. 6 and 2004 Mw5. 2 earthquakes. Engineering geology, 91(2-4), pp. 178-193.

Gosar, A., Roser, J., Sket Motnikar, B. and Zupancic, P. 2010. Microtremor study of site effects and soil-structure resonance in the city of Ljubljana (central Slovenia). Bulletin of earthquake engineering, 8(3), pp. 571-592.

Gosar, A. 2010. Site effects and soil-structure resonance study in the Kobarid basin (NW Slovenia) using microtremors. Natural hazards and earth system sciences, 10(4), pp. 761-772.

Kanai, K. 1983. Engineering Seismology. Tokyo: University of Tokyo Press.

Konno, K. and Ohmachi, T. 1998. Ground-motion characteristics estimated from spectral ratio between horizontal and vertical components of microtremor. Bulletin of the Seismological Society of America, 88(1), pp. 228-241.

Nakamura, Y. 1989. A method for dynamic characteristics estimation of subsurface using microtremor on the ground surface. Railway Technical Research Institute, Quarterly Reports, 30(1), pp. 25-33.

Nakamura, Y. 2000, January. Clear identification of fundamental idea of Nakamura’s technique and its applications. In Proceedings of the 12th world conference on earthquake engineering, 30 January–4 February 2000, Auckland, New Zealand.

SESAME, W. 2004. Guidelines for the implementation of the H/V spectral ratio technique on ambient vibrations: measurements, processing and interpretation. European Commission. Project No. EVG1-CT-2000-00026 SESAME, D23, 12.

Tunggal, P., Ihkyaul, M. and Aris, M. 2014, September. Earthquake microzonation and strength building evaluation at Gelora Bung Tomo stadium Surabaya using microtremor method. In 2014 International Conference on Physics and its Applications (ICOPIA-14), pp. 14-20.




DOI: https://doi.org/10.24815/jarsp.v5i3.26135

Article Metrics

Abstract view : 0 times
PDF - 0 times

Refbacks

  • There are currently no refbacks.


Copyright (c) 2022 zaki mutaram

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

__________________________________________________________________________________________________________________________________
Jurnal Arsip Rekayasa Sipil dan Perencanaan (Journal of Archive in Civil Engineering and Planning).

Terakreditasi SINTA 3 Berdasarkan Surat Keputusan Direktur Jenderal Pendidikan Tinggi, Riset, dan Teknologi, Nomor: 158/E/KPT/2021.

E-ISSN: 2615-1340 P-ISSN: 2620-7567 Organized by Program Studi Magister Teknik Sipil, Fakultas Teknik.

Published by Universitas Syiah Kuala.
Jurusan Teknik Sipil, Fakultas Teknik Universitas Syiah Kuala, Darussalam - Banda Aceh, 23111
Website: http://www.jurnal.usk.ac.id/JARSP/index
Email: jts.mts@usk.ac.id

 Creative Commons License

The Jurnal Arsip Rekayasa Sipil dan Perencanaan (Journal of Archive in Civil Engineering and Planning).
Published by Universitas Syiah Kuala is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Based on work at http://www.jurnal.usk.ac.id/JARSP/index

 

 VIEW STATS