The measurement of microbial air contamination index in the pulmonary ward, intensive care unit and pediatric intensive care unit at dr. Zainoel Abidin hospital, Aceh, Indonesia

TRISTIA RINANDA, SAKDIAH SAKDIAH, RIMA RISTIANTI, VONNA YUNIRA, FEBY VANIA, ANDIKA CITRA BUANA

Abstract


Nosocomial infections are one of the major problems in hospitals. Air is one source of nosocomial infections. Hospitals are filled with many patients, their families, and health workers daily. This large number of people allows the spread of various microorganisms through the air in droplets dispersed through breathing, talking, coughing or sneezing. This study used passive air sampling or settle plate method to measure the air quality in the pulmonary ward, Intensive Care Unit (ICU) and Pediatric Intensive Care Unit (PICU) at dr. Zainoel Abidin Hospital (RSUDZA). The air microbial contamination index was determined by counting the microbial colonies grown on Nutrient Agar and converted to CFU/m3 of air volume using the Polish Standard PN 89/Z-04008/08 Formula. The results showed that the air microbial contamination index in the pulmonary ward, ICU and PICU exceeded the maximum threshold mentioned in the decree of the Minister of Health of the Republic of Indonesia No.1204/SK/X/2004, which was 500 CFU/m3 for the pulmonary ward and 200 CFU/m3 for the Intensive Care Units. Although the findings of this study only represent the large microbial particles pulled by gravity, the high microbial contamination index of each unit trigger air quality alerts. Therefore, adequate air system management and periodic monitoring are needed to improve air quality in the wards and intensive care units at RSUDZA.

References


World Health Organization [WHO]. 2022. Member States Information Session on Infection Prevention and Control (IPC). Available from: https://apps.who.int/gb/MSPI/pdf_files/2022/03/Item1_07-03.pdf

Voidazan S.; Albu S.; Toth R, Grigorescu B.; Rachita A.; Moldovan I. 2020. Healthcare associated infections—a new pathology in medical practice. Int J Environ Res Public Health. 17 (3). DOI: 10.3390/ijerph17030760.

Raoofi S.; Kan FP.; Rafiei S.; Hosseinipalangi Z.; Mejareh ZN.; Khani S., et al. 2023. Global prevalence of nosocomial infection: A systematic review and meta-analysis. PLoS One. 18 (1 January) 1–17. DOI: 10.1371/journal.pone.0274248.

World Health Organization. 2002. Prevention of hospital-acquired infections World Health Organization. 72. Available from: https://iris.who.int/bitstream/handle/10665/67350/WHO_CDS_CSR_EPH_2002.12.pdf.

Bonadonna L.; Briancesco R.; Coccia AM.; Meloni P.; La Rosa G, Moscato U. 2021. Microbial air quality in healthcare facilities. Int J Environ Res Public Health. 8 (12).

DOI: 10.3390/ijerph18126226.

World Health Organization [WHO]. 2009. WHO guidelines for indoor air quality : dampness and mould. Copenhagen. Available from: https://iris.who.int/bitstream/handle/10665/164348/9789289041683-eng.pdf?sequence=1

Kumar P.; Kausar MA,; Singh AB.; Singh R. 2021. Biological contaminants in the indoor air environment and their impacts on human health. Air Qual Atmos Heal. 14 (11) 1723–36. DOI: 10.1007/s11869-021-00978-z.

Wang CC.; Prather KA.; Sznitman J.; Jimenez JL.; Lakdawala S. S.; Tufekci Z, et al. 2021. Airborne transmission of respiratory viruses. Science. 373 (6558). DOI: 10.1126/science.abd9149.

A Working Group of The Scottish Quality Assurance Specialist Interest Group. 2004. Guidelines on Test Methods for Environmental Monitoring for Aseptic Dispensing Facilities. Available from: https://elsmar.com/pdf_files/Environmental Monitoring For Aseptic Dispensing Facilities.pdf

Pasquarella C.; Pitzurra O.; Savino A. 2000. The index of microbial air contamination. J Hosp Infect. 46 (4) 241–56. DOI: 10.1053/jhin.2000.0820.

Haig C. W.; Mackay W. G.; Walker J. T.; Williams C. 2016. Bioaerosol sampling: Sampling mechanisms, bioefficiency and field studies. J Hosp Infect. 93 (3) 242–55.

DOI: 10.1016/j.jhin.2016.03.017.

Stryjakowska-Sekulska M.; Piotraszewska-Pająk A.; Szyszka A.; Nowicki M.; Filipiak M. 2007. Microbiological Quality of Indoor Air in University Rooms. Polish J Environ Stud. 16 (4) 623–32. DOI: 10.12980/APJTB.4.2014C807.

The Ministry of Health of the Republic of Indonesia.2004. Decree No.1204/MENKES/SK/X/2004 on The Health Requirements of Hospital Environment. The Ministry of Health, Republic of Indonesia. 1–64.

Viani I.; Colucci M. E.; Pergreffi M.; Rossi D.; Veronesi L.; Bizzarro A. et al. 2020. Passive air sampling: The use of the index of microbial air contamination. Acta Biomed. 91 92–105. DOI: 10.23750/abm.v91i3-S.9434.

Asif A.; Zeeshan M.; Hashmi I.; Zahid U.; Bhatti M. F. 2018. Microbial quality assessment of indoor air in a large hospital building during winter and spring seasons. Build Environ. 135 (December 2017) 68–73. DOI: 10.1016/j.buildenv.2018.03.010.

Hassan A.; Zeeshan M. 2022. Microbiological indoor air quality of hospital buildings with different ventilation systems, cleaning frequencies and occupancy levels. Atmos Pollut Res. 13 (4). DOI 10.1016/j.apr.2022.101382.

Ibrahim F.; Samsudin E. Z.; Ishak A. R.; Sathasivam J. 2024. The relationship between occupant behaviour and indoor air quality in Malaysian hospital outpatient departments: A multistage cross-sectional study. Heliyon. 10 (14). DOI: 10.1016/j.heliyon.2024.e34454.

Wei X.; Ma X.; Tian F.; Wei Z.; Zhang L.; Hu K. 2024. Sampling and analysis methods of air-borne microorganisms in hospital air: a review. Biotechniques. 76 (8) 395–404. DOI 10.1080/07366205.2024.2372939.

Dimitroulopoulou S.; Dudzińska M. R.; Gunnarsen L.; Hägerhed L.; Maula H.; Singh R., et al. 2023. Indoor air quality guidelines from across the world: An appraisal considering energy saving, health, productivity, and comfort. Environ Int. 178 (August). DOI 10.1016/j.envint.2023.108127.

Saran S.; Gurjar M.; Baronia A.; Sivapurapu V.; Ghosh P. S.; Raju G. M., et al. 2020. Heating, ventilation and air conditioning (HVAC) in intensive care unit. Crit Care. 24 (1) 1–11. DOI 10.1186/s13054-020-02907-5.

Phadke K. S.; Madival D. G.; Venkataraman J.; Kundu D.; Ramanujan K. S.; Holla N., et al. 2021. Novel non intrusive continuous use ZeBox technology to trap and kill airborne microbes. Sci Rep. 11 (1) 1–9. DOI 10.1038/s41598-021-02184-4.

Nagaraj S.; Chandrasingh S,; Jose S.; Sofia B.; Sampath S.; Krishna B., et al. 2022. Effectiveness of a novel, non-intrusive, continuous-use air decontamination technology to reduce microbial contamination in clinical settings : a multi-centric study. J Hosp Infect. 123 15-22.

DOI: 10.1016/j.jhin.2022.02.002.


Full Text: PDF

DOI: https://doi.org/10.24815/jn.v25i1.43797

Refbacks

  • There are currently no refbacks.